TM 55-1930-209-14&P-3
Product water flow
3-3
RO block, product water discharge
rate meter F2
line
Seawater
3-4
Pretreatment skid, between Ro18 and
temperature gauge T1
F1
Coagulant (Hydrapol-50) metering pump controls
3-5
Pretreatment skid, above pressure
gauges
Inhibitor (Hydrapol-100) metering pump controls
3-5
Pretreatment skid, above pressure
gauges
Monitoring system SALINITY display page
3-6
ROWPU space forward bulkhead
Monitoring system HIGH PRESSURE WATER
3-7
ROWPU space forward bulkhead
PUMPS display page
Table 3-3. ROWPU System Valves
Label Identification
Type
Valves
Location
and Valve Function
3-in.
RO1
ROWPU space -on
MEDIA FILTER 1 FLOW;
3-way
pretreatment skid
allows seawater to flow
ball valve
ball valve
to media filter 1 when making
product water and when
backflushing media filter 1
3-in.
R02
ROWPU space -on
MEDIA FILTER 2 FLOW;
3-way
pretreatment skid
allows seawater to flow to
ball valve
media filter 2 when making
product water and when
backflushing media filter 2
3-in.
R03
ROWPU space -on
MEDIA FILTER 3 FLOW;
3-way
pretreatment skid
allows seawater to flow to
ball valve
media filter 3 when making
product water and when
backflushing media filter 3
3-in.
RO4
ROWPU space -on
MEDIA FILTERS FLOW;
3-way
pretreatment skid
allows seawater from media
ball valve
filters to flow to cartridge
filter assembly and HP pump
when making product water
2-in.
RO5
ROWPU space -on
MEDIA FILTER BACKWASH;
globe
pretreatment skid
allows waste water to flow
diaphragm
through RO6 and RO12 directly
valve
overboard during media filter
backflushing
3-in.
RO6
ROWPU space -on
MEDIA FILTER BACKWASH
2-way
pretreatment skid
FLOW; allows adjusting media
ball valve
filter backflushing water flow
to obtain optimum flow
3-2