TM 55-1930-209-14&P-3
Table 3-4. ROWPU System Valves (continued)
2-in.
R07
ROWPU space -in
BRINE THROTTLE VALVE;
2-way
brine discharge line
adjusts brine flow rate
throttling
so that product water
valve
is 1/3 of seawater flow.
Product water flow is controlled
by adjusting valve RO7 and HP
pump diesel engine speed
3/4-in.
RO8
ROWPU space -bottom
CARTRIDGE FILTER DRAIN;
2-way
of cartridge filter assembly
for taking filtered seawater
ball valve
samples and draining cartridge
filter assembly
3/4-in.
RO9
ROWPU space -on end
PRODUCT WATER SAMPLING;
2-way
of each pressure tube
for sampling product water
ball valve
in RO block pressure tube
4-in.
RO10
Void 2 starboard -
MEMBRANE CLEANING
gate valve
above seawater pump
SOLUTION RECIRCULATION;
allows membrane cleaning
solution to recirculate through
seawater pumps
Label Identification
Type
Valves
Location
and Valve Function
3-in.
RO11
ROWPU space -in
CARTRIDGE FILTER TO HIGH
gate valve
HP pump suction line
PRESSURE PUMP; Allows filtered
seawater from cartridge filter
assembly to flow to HP pump
3-in.
RO12
ROWPU space -in-
BRINE TO OVERBOARD
gate valve
board of pretreatment
DISCHARGE; allows brine to
skid
flow overboard from RO block
when making product water
3/4-in.
RO13
ROWPU space -near
MEMBRANE CLEANING
2-way
membrane cleaning
SOLUTION RETURN; allows flow
ball valve
solution drum
of membrane cleaning solution
back to drum
3/4-in.
RO14
ROWPU space -near
MEMBRANE CLEANING
2-way
membrane cleaning
SOLUTION INPUT; allows
ball valve
solution drum
membrane cleaning solution
to flow from drum
3-in.
RO15
ROWPU space -be-
PRODUCT WATER TO STORAGE
gate valve
tween RO block and
TANKS; allows product water
HP pump
from RO block to flow to
drinking water storage tank
3-in.
RO16
ROWPU space -between
HIGH PRESSURE PUMP BYPASS;
gate valve
RO block and HP pump
allows flow of membrane cleaning
solution to RO block bypassing HP
pumps
1/4-in.
RO17
ROWPU space -in
BRINE SAMPLING; for
2-way
brine discharge piping
taking samples of brine
ball valve
near valve RO7
output from RO block
3-in.
R018
ROWPU space -in
SEAWATER TO ROWPU;
gate valve
pretreatment skid
allows flow of seawater to
seawater input piping
ROWPU pretreatment skid
Table 3-2. ROWPU System Valves (continued)
3-3