DECKMASTER6.1.3 Water Hose LineThe water hose line end termination as depicted in Figure 6-5 must be rigidly attached to the winch hub. Thewinch hub incorporates a chute for the water hose line end termination to enter the inside of the hub and be clampedusing the Bolt-Down clamp depicted in Figure 6-6.The suggested procedure for attaching the termination to the inside of the winch hub is as follows:1) Using appropriate overhead handling equipment, position the water hose line termination down thehub chute so that it is resting as shown in Figure 6-7.Note:a)Termination will have to be pulled from the inside of the hub.b)Termination has a 9 inch maximum O. D. and chute maximum width is 9-1/2inches.Extreme care must be taken because of the minimum clearance.2)Rigidly attach termination to chute base with Bolt-Down Clamp as depicted in Figure 6-6. Allnecessary fastener hardware has been provided.6-7
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business