ITEMINTERVALITEMTO BEPROCEDURESCHECK FOR AND HAVEREPAIRED OR ADJUSTEDEQUIPMENTIS NOT READYNO.B D AD W M Q SAINSPECTEDAS NECESSARYAVAILABLE IFTM 55-1930-209-14&P-7Table C-1. Preventive Maintenance Checks and Services for Compressed Air System (Continued)B - BeforeD - DailyQ - QuarterlyD - DuringW- WeeklyS - SemiannuallyA - AfterM - MonthlyA - AnnuallyNOTEAFTER OPERATIONFor less than 12 hour shutdown:1. Turn CHECK AUTO-MANUAL switchon electric controller to MANUAL.2. Push electric controller STOP button.3. Close main supply valve on forwardend of receiver by turning handle atright angle to pipe.4. Follow procedures a through d below.For extended shutdown -12 hours ormore follow procedures e through onbelow.5Compressora. Drain filters 1 and 2 by opening drainvalves on bottom of filtersb. Close drain valves when water and mois-ture have drainedNOTEWeekly or after every 40 hours of equip-ment operation (whichever occurs first).c. Barge 1. Clean compressor air filter bythe following procedures.1) Redtag power panel 1 circuit breaker3P5 indicating. WARNING - DO NOTACTIVATE. REPAIRS BEING MADE.'2) Shut down air compressor system.3) Unscrew by turning clockwise oilcover nut on top of air intake assem-bly on top of compressor.4) Remove oil seal and oil cover.C-9
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business