3-43. 2ND
TM 55-2090-201-14&P
LOCATION
ITEM
ACTION
R E M A R K S
e. To drain water from the
second stage (2):
(1) Close the two inter-
vessel shutoff valves
(6 and 7) on either
stage (2).
(2) Open the drain valve
(8) at the base of the
vessel.
1.
Pump
2.
Second Stage
3.
Oil Dump Light/Button
4.
Supply Pump Selector Switch
5.
Auto Controls Selector Switch
6.
Intervessel Shutoff Valve
7.
Intervessel Shutoff Valve
8.
Drain Valve
3-301