3-43. 2ND
TM 55-2090-201-14&P
LOCATION
ITEM
A C T I O N
R E M A R K S
9.
Air
elimi-
nator
valve
10.
Sight-
glass
(9)
11.
Filter
support
(8)
12.
Filter
element
(7)
Clean using a lint free cloth
and a mild detergent and
water.
Dry thoroughly.
Replace a damaged or defec-
tive separator with a ser-
viceable-like item.
Install.
Refer to paragraph
3-40.
Install.
Handle the filter elements
a. (7)
only by the end caps.
When installing an ele-
ment, insert hand through
the opening in the end cap.
It is important that the filter element be handled
properly.
DO NOT touch or handle the sock area
(side covering) of the elements.
Contamination of
this surface by skin oils may prevent the coalescer
element from functioning properly and cause foaming
of the effluent.
b. Place a filter element (7)
over the threaded element
stand (8).
Position the
element so that it is cen-
tered over the element
positioning guide (11) at-
tached to the striker plate
(12).
3-312