3-43. 2ND
TM 55-2090-201-14&P
L O C A T I O N
ITEM
ACTION
R E M A R K S
b. Solenoid (1) Thread coil leads thru
valve
electrical connections.
coil
(20)
(2) Slide coil (20) over
base.
c. Mini-
probe
(19)
Install.
Use thin wall
socket NSN
5120-00-227-
1465 with 1/2
in.drive
ratchet.
d. Motor
(1) Thread each wire indi-
cable
(16)
vidually thru various
electrical connections
to their tagged compo-
nent end.
(2) Reconnect leads (17)
using connectors (18).
(3) Secure motor cable (16)
by tightening collar
(14) onto connector (15).
e. Tee
Position gasket (10) in
and
place and install cover (9)
pulling using screws (8).
e l b o w
covers
(11, 12,
and 13)
f. Solenoid Install using nameplate (6)
valve
and retaining cap (5).
housing
(7)
g.
Mini-
probe
(1) Reconnect terminals (4).
cover
(2)
(2) Position gasket (3) in
place and install cover
(2) using screws (1).
Restart
Refer to paragraph 2-4.
System
18.
3-320