3-44. 3RD
TM 55-2090-201-14&P
L O C A T I O N
I T E M
A C T I O N
R E M A R K S
Electrical shock or serious injury may result if
electrical power is not shut off before continuing
maintenance on the 3rd stage separator.
2. 3rd stage a. Tee
Remove screws (1), tee cover
electri-
cover
(2) and gasket (3) from tee
cal con-
(6).
nections
and air
b. Leads
(1) Remove connectors (4).
line
(5) and
conduit
(2) Tag and disconnect leads
(7)
(5) and remove wiring.
(3) Remove conduit (7).
1.
Screws
2.
Tee Cover
3.
Gasket
4.
Connectors
5.
Leads
6.
Tee
7.
Conduit
c. Pulling
(1) Remove pulling elbow (1),
elbows
locknut (2), nipple (3),
(1 and
locknut (4), pulling
5) and
elbow (5) and locknut
solenoid
(6).
coil
(11)
(2) Remove retaining cap (7),
nameplate (8), housing
(9) and locknut (10).
3-324