TM 55-2090-201-14&P
4-27. AIR ELIMINATOR VALVE - TYPE C AND D SEPARATORS (Continued).
LOCATION
ITEM
ACTION
REMARKS
Inspection
a. Inspect "0" rings for
wear or damage.
b. Inspect guide pins for
distortion
c.
Inspect valve body for
damaged threads.
Straighten if
distorted.
Service
Dry cleaning solvent P-D-680 used to clean parts is
potentially dangerous to personnel and property.
Avoid repeated or prolonged skin contact.
Do not
use near open flame or excessive heat. Flash point
of solvent is 100° - 138°F (38° - 59°C).
a. Clean valve housing and
needle valve using clean-
ing solvent PD-680 and dry
thoroughly.
b. Clean float using a
clean lint free cloth.
Repair
Replace damaged or defective
parts with serviceable-like
item.
4-99