3-9. SERVICE RAW WATER PUMP POWER CABLES. This task covers:
a. Removal.
b. Inspection.
c. Service.
Materials/Parts:
General Safety Instructions:
Wipes (Appx E, Sec II, Item 76)
WARNING
Equipment Condition:
Make sure the circuit breaker for the raw water pump is turned off
ROWPU shutdown to standby (para. 2-18).
Failure to do so could result in electrocution.
NOTE
This task is limited to cleaning and drying the connectors.
Unscrew the threaded electrical connector (1, Figure 3-4) and separate from connector (2).
INSPECTION.
Look for any dirt, sand, or water in the connector,
a. Clean out all dirt and/or sand.
b. Soak up and wipe dry any water in the connector using the kimwipes.
INSTALLATION.
Plug the connector halves (1 and 2) together and tighten the threaded connector (1).
Figure 3-4. Service Raw Water Pump Power Cable