TM 10-4610-232-12
SERVICE.
a. Open pressure release valve (3).
CAUTION
Pressure gage (6) must read 0 before removing tank cover (4).
b. Remove tank cover(4) by opening bail (5), straps must be removed and tank tipped to drain it and add product water
to fill mark.
c. Add one 4 ounce packagee of fungicide additive.
d. Replace tank cover (4) and lock in place with bail (5).
e. Connect utility air line (8) and charge to 85 psig (586 kPa)
f. Push lever (2) and adjust eyewash flow by turning balancing screw (7) to right or left until flow is equal from both
nozzles.
g. Install dust caps on eyewash nozzles.
3-42 Change 5