Figure 2-83. High Pressure Pump Belt Guard
HIGH PRESSURE PUMP MOTOR.

TM-10-4610-232-34 Water Purification Unit Reverse Osmosis 3 000 GPH Trailer Mounted Flatbed Cargo 22-1/2 Ton 8 Wheel Tandem Model No. WTA-060 Manual
Page Navigation
  256    257    258    259    260  261  262    263    264    265    266  
TM   10-4610-232-34 a. Install guard plate (39) on pump skid (40). Secure with four capscrews (34), washers (35), nuts (36), Iockwashers (37) and washers (38). b. Install spring nuts (33), channels (24), and supports (28 and 29), if removed. c. Install support (29). Secure with two capscrews (30), Iockwashers (31) and washers (32). d. Install supports (28). Secure with capscrews (25), Iockwashers (26) and washers (27). e. Install channels (24) and panels. Secure to supports (28) with capscrews (20), lockwashers (21) and washers (22). f. If removed, secure nameplate (19), with rivets (18) (para. 4-10, TM 10-4610-232-12) to top plate (16). g. Install rails (17) and top plate (16). Secure with ten capscrews (13), Iockwashers (14) and washer (15) h. Install two fastener loops (12) on panel (23). Secure with four capscrews (8), nuts (9), Iockwashers (10) and washers (11). Install straightedge (7). i. If removed, install neoprene trim (6) on screen (5) j. Mount screen (5). Secure with sixteen capscrews (1), Iockwashers, (2), washers (3) and clamp (4) 2-240