HIGH PRESSURE PUMP MOTOR.
HIGH PRESSURE ASSEMBLY, PIPING, VALVES, AND HOSES

TM-10-4610-232-34 Water Purification Unit Reverse Osmosis 3 000 GPH Trailer Mounted Flatbed Cargo 22-1/2 Ton 8 Wheel Tandem Model No. WTA-060 Manual
Page Navigation
  258    259    260    261    262  263  264    265    266    267    268  
TM   10-4610-232-34 WARNING Electrical high voltage can cause serious injury or death. The test requires power to be connected. Always take proper measures to ensure personal safety. Run unit and check for excessive noise, vibration or overheating. a. b. c. d. WARNING This motor is very heavy. Use care to avoid injury from attempting to lift or move the motor. Remove four nuts (1, Figure 2-84), Iockwashers (2) and washers (3). Motor is now free. Attach suitable lifting device to eyebolt (4) and remove motor (5). Remove four capscrews (6), washers (7), nuts (8), Iockwashers (9) and washers (10). Remove motor mounting base (11). NOTE Cable is removed at unit level but repaired at direct support. a. Repair cable (para. 2-7). b. Repair of motor or base is by replacement. a. Mount motor mounting base (11), Secure with four capscrews (6), washers (7), nuts (8), Iockwashers (9) and washers (10). b. Attach suitable lifting device to eyebolt (4) and mount motor (6) onto mounting base (11). c. Secure with four washers (3), Iockwashers (2) and nuts (1). 2-242