Boost pumps (operating in automatic mode) should decrease to idle automatically. Operators at boost pumping
stations should make certain their units have adjusted properly. Operators must also monitor readings on
pressure gages. Pumps that fail to remain primed must be shut off immediately. (Refer to applicable technical
manual.)
(7)
Close gate valves connected to storage assemblies.
(8)
Distribute points may continue to operate as long as enough water remains in storage tanks. When water in
storage tanks drops to inoperable level, shut down operation of distribution points. Shut down engine on 125
GPM pump (refer to applicable technical manual).
c.
Failure of Storage Assembly. If storage assembly fails, TWDS operation is possible ONLY under the following
conditions:
(1) Two storage assemblies are in use, and
(2) The unaffected storage assembly is being used with a distribution point.
(3) To temporarily adapt TWDS operation, proceed as follows:
(a) Close gate valve connected to defective storage tank.
(b) If distribution point is being used with defective storage tank, shut down distribution point (para. 2-13).
Shutdown engine on 125 GPM pump (refer to applicable technical manual).
(c) Notify operators at other stations of equipment failure. Pumps may require adjustment.
d. Failure of Distribution Point. If a distribution point fails, TWDS operation is possible ONLY if two distribution points
are in use. To temporarily adapt TWDS operation, proceed as follows:
(1) Close gate valve connected to storage tank in use with defective distribution point.
(2) Shutdown operation of defective distribution point (para. 2-13). Shutdown engine on 125 GPM pump (refer to
the applicable technical manual).
(3) Notify operators at other stations of equipment failure. Pumps may require adjustment.