(20) Remove elbow valves (11) from ends of two hoses (13).
(21) Push cam arms on discharge hoses (13) forward to open. Remove hoses (13) from end of wye-connection (5).
(22) Repeat steps (15) through (18) with second set of hoses, wye-connection, and gate valve.
(23) Push cam arms on wye-connection (10) forward to open. Remove wye-connection (10) from end of hose (14).
(24) Push cam arms on female reducer (1, Figure 2-47) forward to open. Remove end of hose (2) from female reducer
(1) on suction port of hypochlorination unit (12).
Figure 2-47. Hypochlorination Unit, 125 GPM Pump, and Storage Tank Assemblies
(25) Push cam arms on female quick-disconnect coupling half (3) forward to open position.
(26) Remove reducer (1) from female quick-disconnect coupling half (3).
(27) Unscrew female quick-disconnect coupling half (3) from nipple (4) of unit suction port (5).
(28) Remove nipple (4) from hypochlorination unit suction port (5).
(29) Install plastic dust caps onto hypochlorination unit suction port (5) and discharge ports (6).
(30) Push cam arms on hose (2) forward to open. Remove hose (2) from male coupling half (7) on discharge port of
125 GPM pump (13).
(31) Unscrew and remove male coupling half (7) from 125 GPM pump (13) discharge port.
(32)
Push cam arms on female coupling half (8) forward to open. Remove end of hose (9) from female coupling half
(8) on suction port of 125 GPM pump (13).
(33) Unscrew and remove female coupling half (8) from pump suction port.
(34) Push cam arms on discharge hose (9) forward to open. Remove hose from 2-inch end of reducer (10) attached to
filler/discharge elbow (11) on storage tank.
2-69