TM 10-4320-317-13
(8)
Push cam arms on hose (10) forward to open. Remove flange adapter (11) from end of discharge hose (10).
(9)
Remove 8 nuts (12), lockwashers (13), flat washers (14 and 15), and bolts (16). Remove female flanged
quick-disconnect coupling half (8) from gate valve (24).
(10) Carefully remove gasket (17).
(11) Remove 8 nuts (18), lockwashers (19), flat washers (20 and 21), and bolts (22). Remove flange adapter (11)
from gate valve (24).
(12) Carefully remove gasket (23).
(13) Push cam arms forward to open. Remove first discharge hose (1, Figure 2-44) from female-to-female filler/
discharge elbow (2) of storage tank (3).
Figure 2-44. Discharge Hose and Storage Tank
(14) Separate remaining discharge hoses.
(15) Refer to applicable technical manual for storage tank disassembly procedures.
i.
Disassemble Distribution Points.
WARNING
DANGEROUS CHEMICALS
Calcium hypochlorite can cause injury if not handled properly. Heed safety
measures below.
If calcium hypochlorite comes into contact with skin or eyes, flush right away with
water. Seek medical help.
Mix only in accordance with directions for use.
DO NOT allow calcium hypochlorite to mix with any other materials. This may cause
fire or hazardous gases.
2-66