TM 10-4610-215-10TM 08580A-10/1LEGEND1 Holddown Screw2 HoIddown Ring3 Rupture Disc4 B o d yFigure 3-14. R.O. Pump Rupture Disc and Holderc. Installation.(1) Place the side of new rupture disc (3) that curves upward toward the top.(2) Insert it into body (4).(3) Replace holddown ring (2).CAUTIONTo avoid damaging rupture disc, do NOT overtighten holddown screw.(4) Reinsert holddown screw (1). Tighten until hand tight (snug), then tighten 1/8 turn withwrench.3-8. REPAIR OF CANVAS PRODUCT WATER AND BRINE WATER TANKS.a. General. Canvas tanks with rubber backing are used to store product water and brine water.Sometimes these tanks may be cut or punctured. Tanks then leak and must be repaired.CAUTIONTo avoid possible damage, the site should be free from stones or sharp sticks,be fairly smooth, and covered with the ground cloth before the tank is placed onground.3-32