TM 10-4610-215-24
TM 08580A-24/2
(11) Remove three screws (8) and three lockwashers (9) from lead cover (13), and conduit box (10).
(12) Remove conduit box (10) and gasket (11) from lead cover (13). Discard gasket (11).
(13) Remove four screws (12) from motor casing (23), gasket (14), and lead cover (13). Discard gasket
(14).
(14) Remove four screws (16) from fan-end plate (21) and fan cover (15).
(15) Remove fan cover (15) from fan-end plate (21).
(16) Remove three screws (17) and holding clamp (18) from split hub of fan (19).
(17) Remove fan (19) from rotor shaft (27).
(18) Remove Woodruff key (26) from rotor shaft (27).
NOTE
Mark fan-end plate, pump-end plate, and motor casing with
matching punch pricks to assist alignment during assembly.
(19) Remove four bolts (20) from motor casing (23) and pump-end plate (29).
(20) Remove two grease plugs (22) from fan-end plate (21) and pump-end plate (29).
(21) Strike pump-end plate (29) with a softfaced mallet to break bond with motor casing and remove from
motor casing (23).
(22)
(23)
(24)
CAUTION
Motor casing wiring can be snagged or broken by rotor shaft.
Take care not to damage wires when removing rotor shaft.
Remove rotor shaft (27) from motor casing (23).
Remove wavy washer (24) from fan-end of rotor shaft (27).
Using a bearing puller/press, remove ball bearings (25) and (28) from rotor shaft (27).
3-24