(4) Position contact cover (35) on stationary contact block (36) and install two screws (33) and
lockwashers (34).
(5)
(6)
(7)
(8)
(9)
(10)
(20).
(11)
(12)
Position spindle (31) in overload relays (7) and (9) and install with two screws (30).
Position heater element (29) on overload relays (5) and install with two screws (28).
Install movable contacts (26) and springs (27) into movable contact assembly (13).
CAUTION
To prevent damage, make sure spring is properly positioned on
locating pin and tangs on contact.
Install mounting bracket (22) onto overload relay T1 (5) using two screws (23) and lockvvashers (24).
Install mounting bracket (22) with overload relay T1 (5) attached, to base (20), using two screws (21).
Repeat steps (8) and (9) to install overload relays T2 (7) and T3 (9) and mounting bracket (25) to base
Install movable contact assembly (13) into base (20).
Position stationary contact assembly (17) and insulator block (32) into base (20) and over contacts
(26) of movable contact assembly (13).
CAUTION
In order to prevent damage, be careful not to knock movable
contacts and springs out of position when assembling stationary
contact assembly.
(13) Install two screws (18) and two lockwashers (19) through stationary contact assembly (17), insulator
block (32), and base (20).
(14) Install solid bus wires (16) between terminals of overload relays and stationary contact assembly
L1-T1, L2-T2, L3-T3 (refer to schematic, figure 112).
(15) Slide yoke (15) into operating coil (2).
(16) Slide guide (14) into slot in yoke (15).