TM 10-4610-215-24
TM 08580A-24/2
(1) Remove four screws (1) from front panel (2), gasket (3), and switch case (4).
(2) Remove cover (2) and gasket (3) from switch case (4). Discard gasket (3).
(3) Disconnect and tag three wires from terminal block (5).
(4) Straighten tangs of lockwasher (7) and unscrew socket nut (6) from bourdon tube assembly (11).
(5) Remove socket nut (6) and lockwasher (7) from bourdon tube assembly.
(6) Remove two screws (8) and washers (32) from stop plate (9) from switch case (4).
(7) Remove stop plate (9) from switch case (4).
(8) Carefully lift bourdon tube assembly (11) out of mounting hole and remove from switch case (4).
(9) Remove socket gasket (14) from bourdon tube assembly (11). Discard gasket (14).
(10) Remove two screws (10) from bourdon tube (11) and bracket (12).
(11) Remove bracket (12) and switch assembly (25) from bourdon tube assembly (11).
(12) Remove two screws (13) from contact bracket (15) and bourdon tube assembly (11).
(13) Remove adjusting screw (16), spring (17), and nut (33) from switch bracket (18) and bracket (12).
(14) Remove two screws (19) from top of bracket (12) and bracket clamp (20).
(15) Remove bracket clamp (20) and limit switch assembly (25) from bracket (12).
(16) Remove two nuts (21) and two lockwashers (22) from screws (23).
(17) Remove two screws (23) from switch assembly (25).
(18) Remove switch insulator (24) and switch (25) from switch bracket (18).
(19) Remove two screws (26) from terminal block (5) and switch case (4).
(20) Remove terminal block (5) from switch case (4).
(21) Remove surge dampener (27) from bourdon tube assembly (11).
3-71