TM 10-4610-215-24
TM 08580A-24/2
(3) Clean pump using a stiff brush and cleaning solvent Fed. Spec. P-D-10.
(4) Allow to air dry.
(5) Move pump into work area.
NOTE
Note location of long bolts (1A) for reassembly later.
(6) Remove eight bolts (four long (1A) and four short (1)) from pump casing (2) and adapter (16).
(7) Remove pump casing (2) from adapter (16).
(8) Remove gasket (3) from inside pump casing (2). Discard gasket (3).
(9) Remove impeller bolt (4) and gasket (5) from shaft of motor (19). Discard gasket (5).
(10) Using a puller, remove impeller (6) from shaft of motor (19).
(11) Remove mechanical seal O-ring (7) from back of impeller (6). Discard O-ring (7).
(12) Remove mechanical seal spring (8) from shaft sleeve (10).
(13) Remove shaft key (9) from shaft of motor (19).
(14) Slide shaft sleeve (10) with mechanical seal (11) attached, from shaft of motor (19).
(15) Remove mechanical seal (11) from shaft sleeve (10). Discard mechanical seal (11).
(16) Strike adapter cover (12) with a soft-faced mallet and remove from adapter (1 6).
NOTE
Stationary seat and stationary seat gasket are part of the
mechanical seal. Replace entire mechanical seal during
reassembly.
(17) Remove stationary seat (13) and stationary seat gasket (14) from inside adapter cover (12). Discard
stationary seat (13) and seat gasket (14).
3-155