TM 10-4610-215-24
TM 08580A-24/2
(11)
(12)
(13)
(14)
(15)
(16)
(17)
(18)
(19)
(20)
(21)
Unscrew coupling (14) on drain tube (32).
Release quick disconnect to remove flexible tube (15) from cartridge filter (31).
Unscrew coupling (16) from cartridge filter (31).
Unscrew coupling (17) from outlet pipe (30).
Loosen two hose clamps (19) and remove flexible hose (18) from outlet pipe (30).
Remove two hose clamps (19) from flexible hose (18).
Remove two nuts (20) (figure 3-48, sheet 2 of 2) and two lockwashers (21) from two bolts (22).
Remove two bolts (22) and two flat washers (23) from ROWPU frame and clamp (24).
Remove tank clamp (24) from ROWPU frame and cartridge filter (31).
Loosen two bolts (25) on bracket (26) and push bracket (26) away from cartridge filter (31).
Remove four bolts (27), four lockwashers (28), four nylon flat washers (29), and isolators (33) from
ROWPU frame and cartridge filter (31).
CAUTION
Removal of cartridge filter assembly requires the use of a crane
rated at 1 ton (0.91 tonne) or greater in order to prevent damage
to equipment.
(22) Attach three crane hooks to lifting eyebolts of cartridge filter.
(23) Using a crane, lift cartridge filter (31) just clear of ROWPU floor. Rotate cartridge filter (31) clockwise
enough to gain clearance between outlet pipe (30) and pulse dampener stand.
(24) Remove outlet pipe (30) and drain tube (32) from cartridge filter (31).
(25) Remove cartridge fitter (31 ) from ROWPU.
c. Cleaning.
(1) Clean dirt and corrosion from ROWPU frame behind or under cartridge filter location.
(2) Clean dirt and corrosion from pipe fittings, pipes, and hardware.
3-186