TM 10-4610-232-12
(1)
Remove cap (1) from connector (2) of the waste water port of the ROWPU.
(2)
Remove plug (3) from waste water 45º outlet adapter (4).
(3)
Install waste water 45º outlet adapter (4) to connector (2).
(4)
Remove cap (5) from waste water 45º outlet adapter (4).
(5)
Remove plug (6) from waste water hose (7).
(6)
Install waste water hose (7) onto waste water 45º outlet adapter (4).
(7)
Connect other sections of waste hoses (7) as needed to reach water. The open end of the last section must be placed
into the water at least 50 feet (15 meter) downstream from the ROWPU raw water intake. Six 50 foot (15 meters) long
sections of waste hose are supplied.
(8)
Remove two plugs (8) from two connectors (9) at the two piping drain ports of the ROWPU. One drain pod is located
on each side of the ROWPU.
(9)
Remove caps (10) from two drain-out hoses (11) and connect one drain-out hose to the drain-out ports on each side of
the ROWPU. Place discharge ends of drain-out hoses downstream from raw water intake and away from work areas.
(10)
Connect sump drain hose (12) and clamp (13) to connector (14) on ROWPU. Repeat for sump drain on other side of
ROWPU. Place discharge ends of sump drain hoses downstream from raw water intake and away from work areas.
(11)
Remove any sharp kinks or bends from all wastewater hoses to insure proper drainage in hoses during ROWPU
operation.
2-62.4 Change 12