TM 10-4610-232-12
Figure 2-30. Ground Rod Installation (Sheet 2 of 2)
(MODEL ROWPU-1 ONLY)
(6)
Uncoil ground cables (9), (10), and (11).
(7)
Unscrew the nuts from generator ground lug (12), ROWPU ground lug (13), and trailer ground lug (14) to expose
slots in lugs.
(8)
Connect one end of ground cable (9) to generator ground lug (12) and tighten lug nut.
(9)
Connect one end of ground cable (10) to ROWPU ground lug (13) and tighten lug nut.
(10)
Connect other ends of ground cables (9) and (10) and one end of ground cable (11) to trailer ground lug (14) and
tighten lug nut.
(11)
Install other end of ground cable (11) to grounding rod (1) using cable clamp (2).
(12)
Place front door fire extinguisher on the ground next to ground rod (1).
WARNING
Check to make certain that grounding cable (15) is securely attached to grounding lugs (16 and 17).
Cable (15) should remain attached during transport and deployment, but will be disconnected whenever
the van or high pressure pump assembly are removed from the trailer.
Change 7 2-62.1