TM 10-4610-232-12
f.
Waste Outlet and Sump Drain Hoses (Figure 2-31, Sheet1I of 2). (MODEL WTA-060 ONLY)
Figure 2-31. Waste Outlet and Front Sump Drain Connections (Sheet 1 of 2)
(MODEL WTA-060 ONLY)
WARNING
Under some unusual conditions, air may be pushed out the waste hose (2) causing the end to whip.
Stand clear of hose end by at least 20 ft (6 m) while ROWPU is operating.
NOTE
Be sure to remove caps from ends of waste out hose section
(1)
Connect waste outlet 450 adapter (1) to waste-out connection. Connect waste hose (2) sections as needed to
reach water. The open end is placed back in the water at least 50 ft(15 m) from intake (downstream in a river). Six 50 ft
(15 m) coils of waste out hose are applied. Remove any sharp kinks or bends in hose.
(2)
Connect 45° adapters (3) to drain-out connections. Connect sump drain hoses (4) to drain-out connections and
place discharge ends downstream and away from work areas.
f.1. Waste Outlet and Sump Drain Hoses (Figure 2-3 1, Sheet 2 of 2). (MODEL ROWPU-1 ONLY)
WARNING
Under some unusual conditions, air may be pushed out the waste hose (2) causing the end to whip.
Stand clear of hose end by at least 20 ft (6 m) while ROWPU is operating.
NOTE
Be sure to remove caps front ends of waste out hose section
2-62.2 Change 7