TM 10-4610-232-12
DISASSEMBLY.
a. Refer to Figure 4-37 and disconnect the plug of cable (1) from power cable.
b. Remove eight capscrews (2), Iockwashers (3) and washers (4) and pull panel (26) away from the side of the
ROWPU.
c. Remove four screws (5), nuts (6), Iockwashers (7), washers (8) and remove receptacle assembly (9).
d. Tag and disconnect wires from cable (1) to female plug (10) and male connector (11). Remove screws(12 and 13)
to disconnect ground wire (14).
e. Remove screws(15) and female plug (10).
f. Remove four screws (16), nuts (17), lockwashers (18), washers(19) and cover (20).
g. Remove two screws (21), nuts (22), Iockwashers (23), washers (23A) and male connector (11). Panel (24) is now
free.
h. Remove conduit nut (25) and pull connector with sealing washer (26) and harness(1) out of the enclosure. Loosen
nut (27) and remove retainer (28), bushing (29) and connector with sealing washer (26). Remove gasket (30).
i. Remove screw (31) and dust cap (32), if necessary.
j. Remove ground wire (36) by removing capscrew (33), Iockwasher (34) and flat washer (35).
a. Replace cable (1) if damaged or connector has loose or burned pins.
b. Replace gasket (30) if there is evidence of water leaks.
c. Replace all damaged or missing components.
d. Replace wire markers, if necessary (para. 4-10).
e. Replace damaged rivnuts, if necessary (para. 4-10).
f. Replace desiccant cannister (37) if desiccant color has changed from pink to blue.
a. Install ground wire (36) and secure it to the wall of the ROWPU enclosure with flat washer (35), Iockwasher (34)
and capscrew (33).
b. If removed, install dust cap (32) on receptacle (9) and secure with screw (31).
c. Install gasket (30).
d. Place connector with sealing washer (26) in the enclosure inside the ROWPU and secure with conduit nut (25).
e. Slide nut (26), retainer (28) and bushing (29) on cable (1) and insert the cable through connector (26) into the
enclosure.
f. Install male connector (11) on panel (24) and secure with screws (21), nuts (22), Iockwashers (23) and washers
(23A).
g. Install cover (20) and secure with screws (16), nuts (17), Iockwashers(18) and washers (19).
h. Install female plug (10) and secure to receptacle (9) using screws (15). Install receptacle assembly (9) with four
screws (5), nuts (6), Iockwashers (7) and washers (8).
i. Connect wires from cable (1) to female plug (10) and male connector (11).
j. Connect ground wire(14) and ground wire (36) to female plug (10) using screw (13). Connect ground wire(14) to
male plug (11) using screw (12). Varnish all connections.
k. Place assembled panel (24) against gasket (30) and secure with washers (4), Iockwashers (3) and capscrews (2).
l. Reconnect cable(1) to the input power connector.
Change 2 4-151