TM 10-4610-239-10TM 08580B-10/1CAUTIONWhen connecting hoses on chemical feed cans, be careful not to exert any side force onthe barb hose fittings; they are easily broken.(1) Blue tube to POLYMER can.(2) Green tube to SODIUM HEX can.(3) Red tube to CHLORINE can.(4) Yellow tube to CITRIC ACID can.Figure 2-38. Tubes Attached to Chemical Feed PumpWARNINGChemicals used for operating ROWPU can kill you. The chemicals alone or in mixturecan be dangerous. ALWAYS wear protective clothing and make sure area is wellventilated.CAUTIONUse only chlorine-free water for mixing to prevent damage to ROWPU membranes. Ifthis is the first time the ROWPU is being started, use raw water to mix chemicals. If youare restarting the unit, use brine from storage tank.w.Mix polymer chemical:2-50
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business