TM 10-4610-239-24
TM 08580B-24/3
2-83.
REPLACE LOW-PRESSURE SWITCH.
This task covers:
a. Removal.
b. Inspection.
c.
Installation.
INITIAL SETUP.
a. Tools. Tool Kit (Appx B, Sect III, Item 10).
b. Equipment Condition.
Power shut down (power source manual).
ROWPU shut down (TM 10-4610-239-10).
REMOVAL.
a. Remove four screws (1), lockwashers (2), chain lug (3), cover (4), and gasket (5). Discard lockwashers.
b. Remove screw (6) and terminal lug (7).
c.
Remove two screws (8), washers (9), and terminal lugs (10).
2-182