TM 10-4610-239-24
TM 08580B-24/3
REMOVAL. (Cont)
h. Remove twine (14) and tape (15) from three tagged wire sets.
i.
Remove screw (16) securing grounding wire lug (17).
NOTE
There are three sets of motor wires to disconnect from power source.
Each set is
removed the same. One is shown.
j.
Remove nut (18), lockwasher (19), three terminal lugs (20), and flat washer (21) from screw (22) on each set of
wires (13) that have been untaped.
k.
Install flat washer (21), terminal lugs (20), lockwasher (19), and nut (18) on screw (22).
CAUTION
Wire insulation can be damaged when wires are pulled through elbow. Be careful when
pulling wires.
l.
Remove sealing grip (23) and gasket (24) with wires at elbow (25).
m. Remove booster pump assembly (7) from ROWPU.
INSTALLATION.
CAUTION
Wire insulation can be damaged when wires are pulled through elbow. Be careful when
pulling wires.
a. Position gasket (24) and sealing grip nut (23) on cable assembly (26) and pull four wires through elbow (25) into
conduit box (9).
NOTE
There are three sets of motor wires to connect to power source. Each wire from the
power source is added to a motor wire set in the same way. One is shown.
b. Remove nut (18) and lockwasher (19) from screw (22).
c.
Install three terminal lugs (20) from power source as tagged, lockwasher (19), and nut (18) on screw (2).
2
d. Position grounding wire terminal lug (17) in conduit box (9) and secure with screw (16).
2-180