TM 10-4610-239-24
TM 08580B-24/3
3-25. REMOVAL OF TIMER ASSEMBLY. (MECO)
This task covers: a. Removal. b. Installation.
INITIAL SETUP.
Tools.
Tool Kit (Appx B, Sec III, Item 10).
REMOVAL.
a.
Disconnect power cable (1) from connector receptacle (2).
b.
e
c.
Remove two screws (3), two lockwashers (6) and two flat washers (7).
d.
Remove mounting bracket (8).
e.
Lift timer assembly (4) from crossmember (5) and remove.
INSTALLATION.
a. Locate timer assembly (4) on crossmember (5) install mounting bracket (8) and install two
screws (3), two lockwashers (6) and two flat washers (7).
c.
Connect receptacle (2) to power cable (1).
3-140