TM 10-4610-239-24
TM 08580B-24/3
3-26. REPAIR FRAME.
INITIAL SETUP.
a. Tools.
Tool Kit (Appx B, Sect III, Item 10).
Vernier Caliper (Appx B, Sect m, Items 6 and 9).
Tap Wrench (Appx B, Sect III, Item 7).
Portable Electric Drill (Appx B, Sect III, Items 6 and 9).
Standard Insert Repair Kit (Appx B, Sect III, Items 2 and 9).
Oversize Insert Repair Kit (Appx B, Sect III, Items 2 and 9).
Swage Tool Stop (Appx B, Sect III, Items 2 and 9).
b. Materials/Parts.
Drycleaning Solvent (Appx C, Sect II, Item 16).
Transmission Oil (LO 5-4610-215-12).
c.
General Safety Requirements.
WARNINGS
Compressed air can blow dust into the eyes. Wear eye
protection. Do not exceed 30 psig (207 kPag) air pressure.
Drycleaning solvent AA 711 TYPE I & II is highly toxic and
can ignite organic materials, nitrates, carbides, and chlorates.
Wear eye, skin, and respiratory protection. Use in a well-
ventilated area.
For standard procedures for removal, cleaning, inspection, and installation, refer to Chapter 2, Section VI, of
this manual.
For welding procedures, refer to TM 9-237.
For repair of metal bodies, refer to TM 9-450.