TM 10-4610-239-24
TM 08580B-24/3
3-60. REPAIR BACKWASH CENTRIFUGAL PUMP. (SCOT)
This task covers:
a. Disassembly.
b. Cleaning.
c.
Inspection.
d. Assembly.
INITIAL SETUP.
a.
Tools.
Tool Kit (Appx B, Sec III, Item 10).
Stiff-Bristled Brush (Appx B, Sect m, Item 9).
Arbor Press.
b.
Materials/Parts.
Drycleaning solvent (Appx C, Sect 11, Item 16).
c.
Equipment Condition.
d.
General Safety Requirements.
WARNING
Drycleaning solvent AA 711 TYPE I & II is highly toxic and can ignite
organic materials, nitrates, carbides, and chlorates. Wear eye, skin, and
respiratory protection. Use in a well-ventilated area.
3-258