TM 10-4610-240-24
TM 08580C-24/2
TO 40W4-13-22
Table 2-2. Unit Troubleshooting - continued
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
RAW WATER PUMP NO. 2 ASSEMBLY - continued
Step 4
Remove power at power source and check pump cable assembly for continuity and shorts
a.
If pump cable assembly is defective, replace it. Refer to paragraph 2-21
b
If pump cable assembly is not defective replace centrifugal pump Refer to paragraph.2-22.
2-47