TM 10-4610-240-24
TM 08580C-24/2
TO 40W4-13-22
2-21. CABLE ASSEMBLY (RAW WATER PUMP) MAINTENANCE.
This task consists of..
a. Removal.
b. Test.
c.
Installation
INITIAL SET-UP:
Tools Required
General Mechanics Tool Kit (Appendix B, Section III, Item 4)
Material/Parts Required
Tape, Electrical (Appendix C, Section II, Item 31)
Lockwasher (4) - MS35333-108
Equipment Condition
Reference
ROWPU Shutdown (TM 10-4610-240-10).
Power shutdown (power source manual)
Cable assembly disconnected from ROWPU (TM 10-4610-240-10).
REMOVAL
a.
Unwrap cable assembly (16) from raw water pump assembly frame (15).
b.
Remove two screws (19), cover (18), and gasket (17)
NOTES
Tag wires by set before removal.
There are four sets of wires in conduit box One bundle is shown, the others are similar
c
Pull four wire sets (3) from conduit box (4) Remove twine (12) and electrical tape (7).
d
Remove screw (11) securing grounding wire (13) to conduit box (4)
e
Remove nut (10), lockwasher (9), three wire lugs (8), and flat washer (6) from screw (5) for each set of wires
(3).
f.
Install flat washer (6), lugs of two cream-colored wires (14), lockwasher (9), and nut (10) on screw (5)
CAUTION
Wire insulation can be damaged when wires are pulled through conduit box. Be careful when pulling wires
g..
Remove sealing grip (1) and gasket (2) with wires (14) from conduit box (4)
2-106
126