TM 10-4610-240-24
TM 08580C-24/2
TO 40W4-13-22
2-20. RAW WATER PUMP ASSEMBLY MAINTENANCE - continued.
b.
Cleaning.
(1)
Wash all components with clean water and detergent.
(2)
Rinse components in clean water and dry with wiping rag.
c.
Inspection
(1)
Inspect plug (9), adapter (3) and cap (6) for damaged threads.
(2)
Inspect electrical plug (16) for damaged or missing pins.
(3)
Inspect cable assembly (19) for damaged or missing cover (15).
(4)
Inspect all components for corrosion.
(5)
Inspect pump (14) and frame (20) for loose or missing hardware.
d.
Repair.
(1)
Replace damaged components.
(2)
Replace gaskets (4 and 5).
e.
Assembly.
(3)
Install gasket (5) in cap (6)
(4)
Install gasket (4) in adapters (3).
(5)
Install information plate (2) on frame (20) with two screws (1)
(6)
Install screw (13), two chains (7 and 10), flat washer (12), and nut (11)
(6)
Apply anti-seize tape to threads of drain cocks (8) Be sure to wrap tape in same direction as thread.
(7)
Install two drain cocks (8) in pump (14).
(8)
Install cap (15), starwasher (17), and screw (18) on electrical plug (16)
(9)
Wind cable assembly (19) onto frame (20)
INSTALLATION
a
Install cap (6) and plug (9).
b
Close drain cocks (8)
c
Operate raw water pump and test for leaks (TM 10-4610-240-10).
2-104
124