TM 10-4610-240-24
TM 08580C-24/2
TO 40W4-13-22
2-21. CABLE ASSEMBLY (RAW WATER PUMP) MAINTENANCE- continued. .
TEST
CAUTION
The following tests are performed to determine if the cable assembly is defective Before testing, cable
assembly must be disconnected from the motor Failure to disconnect cable can result in false test
indications
Make sure wire terminals (21) are not touching each other
a.
FROM
TO
PIN
WIRE COLOR
A
BLACK
B
WHITE
C
RED
D
GREEN
E
BARE
b.
If continually does not exit between two positions replace cable assembly
2-108
128