TM 10-4610-240-24
TM 08580C-24/2
TO 40W4- 13-22
2-22. CENTRIFUGAL PUMP (RAW WATER PUMP) MAINTENANCE.
This task consists of
a. Removal
b. Installation
INITIAL SET-UP:
Tools Required
General Mechanics Tool Kit (Appendix 13, Section III, item 4)
Material/Parts Required
Lockwashers (2) - MS35338-141
Equipment Condition
Reference
ROWPU Shutdown (TM 10-4610-240-10).
Power shut down (power source manual)
External hoses disconnected (TM 10-4610-240-10).
REMOVAL
a. Remove locknut (14), flat washer (13), two chain lugs (12), and screw (2).
b. Remove hose cap (6), hose plug (5), straight adapter (7), swivel adapter (4), and elbow (3).
c.
Remove two nuts (9), lockwashers (10), flat washers (11), and screws (15).
d. Remove centrifugal pump (8) from frame (1).
INSTALLATION
a. Position centrifugal pump (8) on frame (1).
b. Install two screws (15), flat washers (11), lockwashers (10), and nuts (9)
c.
Install elbow (3), swivel adapter (4), straight adapter (7), hose plug (5), and hose cap (6).
d. Install screw (2), two chain lugs (12), flat washer (13), and locknut (14).
e. Start raw water pump and check for leaks (TM 10-4610-240-10).
2-112