2-41.
GATE VALVE (VENT VESSELS) MAINTENANCE- continued.
INSTALLATION
a.
Apply anti-seize tape to male fittings. Be sure to wrap tape in same direction as pipe thread.
b.
Position gate valve (14) in vice.
c.
Install nipple (5), adapter (20), and bushing (4) on gate vale (14)
d.
Install insulation tape (18) and ring filler (15) on nipple (5)
e.
Install adapter (13) on gate valve (14)
f.
Position gate valve (14) and attached parts in control panel (2)
g.
Install clamp halves (10 and 11), screws (9), and two nuts (12).
h.
Install gasket (8).
i.
Install clamp halves (6 and 16), screws (17), and nuts (7).
j.
Tighten two nuts (3 and 19)
k.
Close gate valve (14).
l.
Install cap (1).
m.
Operate ROWPU (TM 10-4610-240-10). Check for leaks and proper operation.