TM 10-4610-240-24
TM 08580C-24/2
TO 40W4-13-22
2-42. FLOW METER (PRODUCT WATER) MAINTENANCE - continued.
INSTALLATION
NOTE
Apply anti-seize tap to all male pipe threads before installation.
a
If removed, install adapter (24) on pipe section (20).
b.
Install pipe sections (6 and 20) on flowmeter (15)
CAUTION
Pipe section can be badly damaged by corrosion if it contacts
strap Be sure to separate pipe section from strap with insulating
tape.
c.
Install insulating tape (16) on pipe section (20) where two piece strap (17) will clamp.
d.
Position flowmeter (15) in cutout on control panel (1) and position end of pipe section (20) through hole in
control panel
e.
While supporting flowmeter (15), install two-piece strap (17), two screws (22), lockwashers (19), and nuts
(18).
f
Tighten two nuts (21)
g
Position bracket (12) on flowmeter (15) and install four starwashers (13) and screws (14).
h.
Install four screws (5), lockwashers (4), and nuts (3).
i.
Install gasket (8), clamp halves (10), two screws (11), and nuts (7) on pipe sections (6 and 9)
j.
Operate ROWPU (TM 10-4610-240-10). Check for leaks and proper operation.
2-168