TM 10-4610-240-24
TM 08580C-24/2
TO 40W4-13-22
2-64. CABLE ASSEMBLY W40 (GENERATOR) MAINTENANCE (MODELS WPES-1 AND WPES-3) - continued
TEST
CAUTION
The following test is performed to determine if the cable assembly is defective.
Before testing, cable assembly must be disconnected.
Make sure wire ends are not touching each other.
a. Using multimeter, test cable assembly for continuity between cable jack sockets and ends of wires.
CABLE ASSEMBLY W40 CONTINUITY TEST
FROM
TO
PIN
WIRE COLOR
B
BLACK
C
WHITE
A
RED
N
GREEN
G1, G2, G3, G4
BARE
b. If continuity does not exist between any two points, replace the cable assembly.
2-229