TM10-4610-240-24
TM 08580C-24/2
TO 40W4-13-22
2-62. CABLE ASSEMBLY (R.O. PUMP) MAINTENANCE - continued.
INSTALLATION
a
If removed, install elbow (15) on conduit box (19).
b
If removed, position gasket (18) and conduit box (19) on motor (17) and install four starwashers (25) and
screws (24).
c.
Carefully pull four wires (16) through elbow (15) into conduit box (19).
d
Screw cable connector (14) onto elbow (15).
e
Install wire lug (2) of ground wire (1) with screw (3).
NOTE
There are three wire bundles in conduit box. All are assembled the same One is
shown, the others are similar.
f
Install two wire lugs (9), flat washer (10), screw (11), lockwasher (8) and nut (7).
g
Using electrical tape (4), wrap bare metal parts on each wire bundle (6).
h
Using twine (5), secure electrical tape (4) on each wire bundle (6) and position three bundles in conduct box
(19).
i.
Position gasket (20) and conduit box cover (21) on conduit box (19) and install four starwashers (22) and
screws (23).
j.
Operate ROWPU and check for proper operation (TM 10-4610-240-10).
2-224