TM 10-4610-240-24
TM 08580C-24/2
TO 40W4-13-22
3-45. CONTROL BOX ASSEMBLY MAINTENANCE.
This task consists of:
a.
Removal
b. Disassembly
c.
Cleaning
d. Inspection
e.
Repair
f. Assembly
g.
Installation
INITIAL SET-UP:
Tools Required
General Mechanics Tool Kit (Appendix B, Section III, Item 4)
Materials/Parts Reauired
Rags, wiping (Appendix C, Section II, Item 23)
Gasket- MS51007-12
Lockwasher (30) MS35338137
Lockwasher (4) - MS35338-138
Lockwasher- MS35338-136
0-ring - 5262
Personnel Required
Two (2)
Equipment Condition
Reference
ROWPU shut down (TM 10-4610-240-10).
General Safety Instructions
WARNING
High voltages in this equipment can cause serious injury or death. Be certain
that all power is removed before performing maintenance.
Lifting heavy/difficult to handle equipment incorrectly can cause serious
injury.
REMOVAL
a.
Remove 14 screws (9), lockwashers (8), flat washers (7), and lower control box cover (6).
b.
Remove cable connector (15) from receptacle connector (16).
NOTE
There are two electrical cables installed on terminals in the control box
assembly. Both are removed the same.
Tag wires before removal.
c.
Remove three screws (11) and wires (1).
3-246