TM 10-4610-240-24
TM 08580C-4/2
TO 40W4-13-l2
3-45. CONTROL BOX ASSEMBLY MAINTENANCE - continued.
ELECTRICAL RELAYS K10 AND K11.
a.
Remove 14 screws (14) lockwashers (15) and flat washers (16). Lower control box cover (13).
b.
Solder 13 wires (5) to pins on relay K10 (2) as tagged.
c.
Position relay K10 (2) on bracket (6) and install four flat washers (9), new lockwashers (7), and nut (8).
d.
Position relay K11 (3) on bracket (6). Install four flat washers (9), new lockwashers (7), nuts (8), screws (10),
lockwashers (11) and nuts (12).
e.
Solder 11 wires (4) to pins on relay K11 (3) as tagged.
f.
Install control box cover (13) and install but do not tighten 14 screws (14), lockwashers (15), and flat washers
(16).
3-262