3-45. CONTROL BOX ASSEMBLY MAINTENANCE - continued.
INSTALLATION.
WARNING
High voltages in this equipment can cause serious injury or death. Be certain that all
power is removed before performing maintenance
a.
Remove 14 screws (9), lockwashers (8), and flat washers (7) Lower control box cover (6)
WARNING
The control box assembly is heavy/difficult to handle. Two people are needed to lift it to
prevent personal injury or damage to the equipment
b.
Support control box assembly (5) and install four screws (17), flat washers (14), new lockwashers (13), and
nuts (12).
c.
Install cable connector (15) on receptacle connector (16)
NOTE
There are two electrical cables installed on terminal in the control box assembly. Both
are installed the same.
d.
Position electrical cable (2) in place and install new cable grip locknut (10) on cable grip (3).
e.
Position three wires (1) on terminals as tagged and install three screws (11).
f.
Repeat steps d and e for electrical cable (4).
g.
Position control box cover (6) and install 14 screws (9), lockwashers (8) and flat washers (7).
3-264