TM 10-4610-40-24
TM 08580C-24/2
TO 40W4-13-22
3.46. WIRING HARNESSW1 MAINTENANCE.
This task consists of:
a.
Removal
b. Inspection
c.
Repair
d. Test
e.
Disassembly
f. Assembly
g.
Installation
INITIAL SET-UP:
Tools Required
General Mechanics Tool Kit (Appendix B, Section III, Item 4).
Soldering Gun Kit (Appendix B, Section III, Item 3)
Multimeter (Appendix B, Section III, Item 3).
Electrical Repair Kit (Appendix B, Section III, Item 3)
Crimping Tool (Appendix B, Section III, Item 3).
Wire Stripper (Appendix B, Section III, Item 3).
Lockwasher (4) - MS35338137
Material/Parts Required
Tape, Electrical (Appendix C, Section II, Item 31)
Equipment Condition
Reference
ROWPU shutdown (TM 1ll10-240-10).
Power shut down (power source manual).
Control box assembly removed (paragraph 345).
NOTE
Procedures are typical and can be used for all wiring harnesses in the ROWPU. Wiring
harness in control box assembly is shown.
REMOVAL
a.
Remove four nuts (4), lockwashers (5), flat washers (6), and screws (10).
b.
Remove receptacle connector (2) and gasket (1). Discard gasket.
NOTE
Note routing of wiring harness.
c.
Cut all wire ties and remove all clamps.
NOTE
Tag all wires before removal
There are multiple wires with terminal lugs at end. One is shown.
e.
Remove screw (7) and remove wire lug (8). Install screw in place.
f.
Remove wiring harness (9).
3-266