TM 10-461-241-10
TO 40W4-13-41
2-7. ROWPU ASSEMBLY AND PREPARATION FOR USE - cont.
e.
Install Raw Water Pump No. 1 Quick Disconnect and Strainer Fittings. Refer to figure 2-26.
NOTE
· During installation, apply antiseize tape (from storage chest) to pipe threads of quick disconnect
fittings.
· Raw water pump No. 1 uses both a male and female quick disconnect fitting. Raw water pump
No. 2 uses two female quick disconnect fittings.
(1)
If required, mark frame of one raw water pump as "No. 1".
(2)
Unscrew plugs from suction and discharge couplings.
(3)
Install 1 1/2-inch female quick disconnect fitting on suction coupling.
(4)
Install 1 1/2-inch male quick disconnect fitting on discharge coupling.
(5)
Close drain and vent valve on raw water pump No 1.
(6)
Install 1 1/2-inch male quick disconnect fitting on raw water strainer.
Figure 2-26. Raw Water Pump No. 1 Quick Disconnect Fittings.
2-51