2-7. ROWPU ASSEMBLY AND PREPARATION FOR USE - cont.
f.
Install Raw Water Pump No. 2 Quick Disconnect Fittings. Refer to figure 2-27.
NOTE
· During installation, apply antiseize tape (from storage chest) to pipe threads of quick
disconnect fittings.
· Raw water pump No. 1 uses both a male and female quick disconnect fitting. Raw water pump
No. 2 uses two female quick disconnect fittings.
(1)
If required, mark frame of remaining raw water pump as "No. 2".
(2)
Unscrew plugs from suction and discharge couplings of raw water pump No. 2.
(3)
Install 1 1/2-inch female quick disconnect fitting on suction coupling of raw water pump
No. 2.
(4)
Install 1 1/2-inch female quick disconnect fitting on discharge coupling of raw water pump
No. 2.
(5)
Close drain and vent valves on raw water pump No. 2.
Figure 2-27. Raw Water Pump No. 2 Quick Disconnect Fittings.