TM 10-4610-241-24
TO 40W4-13-42
2-24.1
OCEAN INTAKE STRUCTURE REPAIR (MODELS H-9518-1, H-9518-2, AND H-9518-3).
This task consists of:
a. Disassembly
c. Inspection
e. Assembly
b. Cleaning
d. Repair
INITIAL SET-UP:
Tools Required
General Mechanics Tool Kit (Appendix B, Section III, Item 5)
Material/Parts Required
Detergent (Appendix C, Section II, Item 5)
Rags, Wiping (Appendix C, Section II, Item 14)
Tape, Anti-seize (Appendix C, Section II, Item 19)
Coupling (TM 10-4610-241-24P)
Cam-lock replacement fitting (TM 10-4610-24l-24P)
Hose Clamps (TM 10-4610-241-24P)
Adhesive (TM 10-4610-241-24P)
Gaskets (TM 10-4610-241-24P)
Water
Equipment Condition
Reference
Ocean Intake Structure removed from system (TM 10-4610-241-10)
a.
Disassembly.
(1)
Disconnect two wellpoint assemblies (1), and each hose assembly (2) by releasing the quick disconnect
fitting arms.
(2)
Remove male quick disconnect fitting (3) from gate valve (4) by turning counterclockwise.
(3)
Remove gate valve (4) from nipple (5) by holding nipple with pipe wrench and turning valve
counterclockwise.
(4)
(5)
Remove nipple (5) from raw water pump No. 1(6) by turning counterclockwise.
Remove the two male (7 and 8) and female (9) fittings from the tee assembly ( 10) by turning
counterclockwise.
(6)
Remove check valve (11) from tee assembly (10) by turning counterclockwise.
NOTE
For gate valve and fittings, refer to Paragraph 2-24 for repair.
2-120.2 Change 1