TM 10-4619-241-24
TO 40W4-13-42
2-24.1 OCEAN INTAKE STRUCTURE REPAIR (MODELS H-9818-1, H-9518-2, AND
H-9618-3) - continued.
(4)
(5)
(6)
(7)
(8)
(9)
(10)
(11)
NOTE
Install check valve so that water flows from the tee.
Install the check valve (11) into the tee (10).
Install the two male fittings (7 and 8) into the tee (10).
Install the female fitting (9) onto the check valve (11).
Install nipple (5) on raw water pump No. 1 by turning clockwise.
Install gate valve (4) onto nipple (5) by turning clockwise.
Install male fitting (3) into gate valve by turning clockwise.
Install wellpoint assemblies (1) and hose assemblies (2) as required for operation.
Operate Ocean Intake Structure (TM 10-4610-241-10).
Change 1 2-120.7