TM 10-4610-241-24
TO 40W4-13-42
2-25.
CHEMICAL CANS AND FRAME REPAIR - continued .
(7)
Pull bottom of suction tube (13) toward front of can while pushing down from the top and remove suction tube (13)
and attached strainer (16) from inside of can (6).
(8)
Unscrew strainer (16) from suction tube (13).
(9)
Unplug dust cap (17) and remove coupling (18), dust cap and adapter (19).
(10) Holding fitting (20) from inside can (6), to keep it from turning, unscrew knurled nut (21) and remove nut and
gasket (22).
(11)
Remove fitting (20) from inside of can (6).
2-123